44 Farmall H Charging ProblemModerator: Team Cub
2 posts
• Page 1 of 1
44 Farmall H Charging ProblemMy 44 Farmall H has what I believe is a 6 volt generator w/regulator mounted on it from a Super H. The instrument panel gage indicates it is charging between 9 - 10 volts.. Seems a little high to me.. The original 4 position light switch is still on the tractor but at present is not connected as the hi/low charge capability is not needed with this particular generator/regulator and I don't have a good 3 positiion switch to replace it with. Any input on this would be appreciated as the electrical systems are a mystery for me. Thanks.
Gene Chestnutt
Gene, assuming you still have the original gauges, that would be 9-10 amps, not volts, which is good, and should drop back to near zero as the engine runs. An H takes quite a bit of current to recharge the battery after starting, so it will take it quite a while to taper off.
"The Constitution is not an instrument for the government
to restrain the people, it is an instrument for the people to restrain the government lest it come to dominate our lives and interests." Patrick Henry
2 posts