44 Farmall H Charging Problem

Farmall H, HV & Super H, 1939-1954

Moderator: Team Cub

Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.

44 Farmall H Charging Problem

Postby Gene Chestnutt » Thu Apr 19, 2007 11:16 pm

My 44 Farmall H has what I believe is a 6 volt generator w/regulator mounted on it from a Super H. The instrument panel gage indicates it is charging between 9 - 10 volts.. Seems a little high to me.. The original 4 position light switch is still on the tractor but at present is not connected as the hi/low charge capability is not needed with this particular generator/regulator and I don't have a good 3 positiion switch to replace it with. Any input on this would be appreciated as the electrical systems are a mystery for me. Thanks.
Gene Chestnutt
Gene Chestnutt
Cub Star
Cub Star
 
Posts: 81
Joined: Sat Feb 08, 2003 10:57 pm
Location: Raymondville, Texas

Postby John *.?-!.* cub owner » Fri Apr 20, 2007 7:15 am

Gene, assuming you still have the original gauges, that would be 9-10 amps, not volts, which is good, and should drop back to near zero as the engine runs. An H takes quite a bit of current to recharge the battery after starting, so it will take it quite a while to taper off.
"The Constitution is not an instrument for the government
to restrain the people, it is an instrument for the people to restrain the
government lest it come to dominate our lives and interests." Patrick Henry
User avatar
John *.?-!.* cub owner
Team Cub Guide
Team Cub Guide
 
Posts: 19093
Joined: Sun Feb 02, 2003 2:09 pm
Location: Mo, Potosi
Zip Code: 63664
Tractors Owned: 47, 48, 49 cub plus Wagner loader & other attachments. 41 Farmall H.


Return to Farmall H & Super H

Who is online

Users browsing this forum: No registered users and 1 guest