gererator questionsOk
This is a little more then just a Farmall A generator. I posted about this over a year ago and I can locate the post in the forumn. I am using an old Chrysler Corparation 6 volt generator/hydraulic pump all in one unit. It was used for hydraulic convertable tops. I took it off a doodle bug tractor. My question is the generator does not have markings on it for the Feild or the Arm. How do you know which one is which? can you look down at it with the pulley up and the arm be the one on the left and the feild on the right? The one post is bigger then the other does that tell me anything? any help with finding out which one is which would be nice. I want to wire this in using a voltage regulator by-passing the high low on the 4 way switch but yet still use that for the lights would anyone know how to tell me to wire this up? Thanks Chad "don't find fault, find a remedy"
1948 Cub, 1945 A, 1955 100
Re: gererator questionsThe large post should be the armature.
Bigdog
If you can't fix it with a hammer, you've got an electrical problem. My wife says I don't listen to her. - - - - - - - - Or something like that! http://www.cubtug.com
Re: gererator questionsThanks Big Dog
If that is true if I take my volt meter to the Arm to Ground will that show me the charging volts coming out of the genny? "don't find fault, find a remedy"
1948 Cub, 1945 A, 1955 100
Re: gererator questionsYes
Bigdog
If you can't fix it with a hammer, you've got an electrical problem. My wife says I don't listen to her. - - - - - - - - Or something like that! http://www.cubtug.com
Re: gererator questionswell I took a voltage reading at the battery before starting it was 6.31volts. I then took the positive wire of my meter to the arm on the gen and the negative to ground and at half throtal I got .31 volts and at full throtal I got .45 volts. I think the generator is shot.
I almost have to find a way to rebuild it since the Hyd. pump bolts on the end of it. any suggestions? Chad "don't find fault, find a remedy"
1948 Cub, 1945 A, 1955 100
Re: gererator questionsDid you polarize the generator first?
Bigdog
If you can't fix it with a hammer, you've got an electrical problem. My wife says I don't listen to her. - - - - - - - - Or something like that! http://www.cubtug.com
Re: gererator questionsCouple of choices. Take it to an automotive electrical repair shop. Take it apart and see what you need to repair, replace. Bearings and brushes should be readily available. Big problem will be the commutator - if it needs to be turned and undercut. I have an excuse. CRS.
Re: gererator questionsBig dog
I am just trying to take readings with the volt meter I am not sure the wiring is hooked up right so I didn't bother polarizing it using the voltage reg jumping the bat to the gen. Can you just polarize the generator by itself? Eugene. The bearings all seem good it spins very easy no noise so I am guessing the brushes? Should the brush pull away when you pull back on the spring loaded retainer? "don't find fault, find a remedy"
1948 Cub, 1945 A, 1955 100
Re: gererator questionsChad - polarize by applying battery voltage from the generator case (ground) and the A (armature) terminal on the generator.
On the brushes - yes, if you pull the holder clip back the brush should slide in the brush holder. Pull the brush out and see how much brush length you have left. The contact surface of the brush should give you some idea of what the commutator looks like. If it is smooth the commutator is probably in good shape. If the brush is grooved, so is the commutator. Bigdog
If you can't fix it with a hammer, you've got an electrical problem. My wife says I don't listen to her. - - - - - - - - Or something like that! http://www.cubtug.com
Re: gererator questions
Ground the generator F terminal when you do this test.
Re: gererator questionsDarrell, are you sure you typed that correctly? "The Constitution is not an instrument for the government
to restrain the people, it is an instrument for the people to restrain the government lest it come to dominate our lives and interests." Patrick Henry
Re: gererator questionsWell - now that I re-read it - no............ need another cup of coffee...
Bigdog
If you can't fix it with a hammer, you've got an electrical problem. My wife says I don't listen to her. - - - - - - - - Or something like that! http://www.cubtug.com
Re: gererator questionsJim
I took the same readings with the F grounded and I do not think it got better possibly worse I will re check it tonight. Chad "don't find fault, find a remedy"
1948 Cub, 1945 A, 1955 100
Re: gererator questionsJim
I don't know how this can work but I did the test with the feild on the gen grounded and checked the arm with the volt meter and it read 32 volts. un-hooked ground from feild and tested and it reads about .4 volts on high throtal. What does this mean? "don't find fault, find a remedy"
1948 Cub, 1945 A, 1955 100
Re: gererator questionsSounds like the generator is OK.
Bigdog
If you can't fix it with a hammer, you've got an electrical problem. My wife says I don't listen to her. - - - - - - - - Or something like that! http://www.cubtug.com