This site uses cookies to maintain login information on FarmallCub.Com. Click the X in the banner upper right corner to close this notice. For more information on our privacy policy, visit this link:
Privacy Policy

NEW REGISTERED MEMBERS: Be sure to check your SPAM/JUNK folders for the activation email.

Generator

Farmall Super A, AV, 100, 130, & 140 1939 - 1973
Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
DanR
10+ Years
10+ Years
Posts: 1631
Joined: Fri Dec 22, 2006 6:28 am
Zip Code: 37743
Circle of Safety: Y
Location: Tennessee East

Generator

Postby DanR » Tue Feb 09, 2010 7:14 pm

The original generator on the SA has finally died. Took it to the shop and it will be $80-$120 to rebuild. So, a 12v one wire alternator is $60 plus the lights, new battery, etc. Has anyone put an alternator on a SA? What problems am I likely to encounter? 6v original has always been my favorite on early Farmall tractors but now, maybe it's time for a change. All comments welcome.
47 Cub (Glenda)
52 Super A
62 Cub (Genie)
43 H
42 M
In all things know which way the wind is blowing.

SPONSOR AD

Sponsor



Sponsor
 

User avatar
markwayne
10+ Years
10+ Years
Posts: 271
Joined: Thu Apr 17, 2008 8:12 pm
Zip Code: 24550
Tractors Owned: 1952 F Cub
Location: VA, Evington
Contact:

Re: Generator

Postby markwayne » Tue Feb 09, 2010 8:58 pm

The price sounds ridiculous. See what an exchange is on line. Check Ebay. There are 6v alternators too so you don't have to change everything. But I would resist the alternator route. Generators are not magic I have fixed several. often all they need is new brushes and a cleaning of the commutator if the bushings are still good.
grandpops 52 Fcub #151651, 193 plow, 144 cultivators, 174 runner planter, Type C Duplex hopper, 53 Fertilizer Unit, front/mid mount blade, IH but non Cub 4 foot disc, non IH peg tooth harrow, and one of the infamous and much maligned belt pulleys.

User avatar
SONNY
10+ Years
10+ Years
Posts: 4107
Joined: Thu Nov 09, 2006 11:26 pm
Zip Code: 61722

Re: Generator

Postby SONNY » Wed Feb 10, 2010 12:47 pm

Thats what Dr. Bill charges for re-build here in town.---pretty much standard price now days. thanks; sonny

User avatar
markwayne
10+ Years
10+ Years
Posts: 271
Joined: Thu Apr 17, 2008 8:12 pm
Zip Code: 24550
Tractors Owned: 1952 F Cub
Location: VA, Evington
Contact:

Re: Generator

Postby markwayne » Wed Feb 10, 2010 1:14 pm

Compared to fixing it with this kit it is. Armatures can fail but seldom. If the commutator needs more than a cleaning up with a strip of sand paper on a flat stick (file) see if someone with a lathe can clean it up. My friend told me his dad used to turn them between centers on a wood lathe, didnt get any details.
guessing he used a piece of hose to drive it.

http://cgi.ebay.com/ws/eBayISAPI.dll?Vi ... 602_263622
grandpops 52 Fcub #151651, 193 plow, 144 cultivators, 174 runner planter, Type C Duplex hopper, 53 Fertilizer Unit, front/mid mount blade, IH but non Cub 4 foot disc, non IH peg tooth harrow, and one of the infamous and much maligned belt pulleys.

DanR
10+ Years
10+ Years
Posts: 1631
Joined: Fri Dec 22, 2006 6:28 am
Zip Code: 37743
Circle of Safety: Y
Location: Tennessee East

Re: Generator

Postby DanR » Wed Feb 10, 2010 2:16 pm

I had a good talk with the generator guy this morning. BTW he does a lot of tractor work. The Delco alternator is $60 complete. The Hitachi or Honda is $80. We talked about dropping resisters and 6v alternators. He said 6v alternators do strange things to a tractor and does not recommend this. Does the tractor turn fast enough to start? If so put a dropping resister at the 12v alternator and leave everything alone. Do you have starting problems especially in winter? Do you have 6v battery problems? Do you have 6v grounding problems? If so go 12v all the way and be trouble free. One other option is to put a dropping resister at the coil to keep it 6v and if you don't want to change light bulbs wire the light switch from the coil resister. So, I have a good 12v battery and a 12v coil somewhere. Three light bulbs about $3. I can't see any other expense except material to build a new mounting bracket if I don't already have it. Now if I can remember to switch the battery cables and reverse the ammeter. :D
47 Cub (Glenda)
52 Super A
62 Cub (Genie)
43 H
42 M
In all things know which way the wind is blowing.

Song
10+ Years
10+ Years

Re: Generator

Postby Song » Wed Feb 10, 2010 2:53 pm

The 12V alternator on my SA makes it very very hard to close the hood on that front side. It is right in the way of the pull latch.

DanR
10+ Years
10+ Years
Posts: 1631
Joined: Fri Dec 22, 2006 6:28 am
Zip Code: 37743
Circle of Safety: Y
Location: Tennessee East

Re: Generator

Postby DanR » Wed Feb 10, 2010 2:56 pm

Thanks for the warning. I'll try to make more room when I make the mounting bracket . Thanks, Dan
47 Cub (Glenda)
52 Super A
62 Cub (Genie)
43 H
42 M
In all things know which way the wind is blowing.

Song
10+ Years
10+ Years

Re: Generator

Postby Song » Wed Feb 10, 2010 3:01 pm

DanR wrote:Thanks for the warning. I'll try to make more room when I make the mounting bracket . Thanks, Dan


I will be doing something to mine to be able to close that hood all the way. Mainly for the reason there is no top adjustment on it to keep it tight. I might go with a 12V generator so I can have the closer to the original size of it.

User avatar
Don McCombs
Team Cub Mentor
Team Cub Mentor
Posts: 17480
Joined: Mon Feb 03, 2003 6:45 am
Zip Code: 21550
Tractors Owned: "1950 Something" Farmall Cub
1957 Farmall Cub w/FH
1977 International Cub w/FH
1978 International Cub
1948 Farmall Super A
Circle of Safety: Y
Location: MD, Deep Creek Lake

Re: Generator

Postby Don McCombs » Wed Feb 10, 2010 3:20 pm

Here's the alternator location on mine.

Image
Don McCombs
MD, Deep Creek Lake

Image
Proud Member of Maryland Chapter 39

The best teachers are those who show you where to look, but don't tell you what to see.
A. K. Trenfor

User avatar
SONNY
10+ Years
10+ Years
Posts: 4107
Joined: Thu Nov 09, 2006 11:26 pm
Zip Code: 61722

Re: Generator

Postby SONNY » Wed Feb 10, 2010 3:42 pm

Looks great Don!---Show tractor?---really shines! thanks; sonny

User avatar
Don McCombs
Team Cub Mentor
Team Cub Mentor
Posts: 17480
Joined: Mon Feb 03, 2003 6:45 am
Zip Code: 21550
Tractors Owned: "1950 Something" Farmall Cub
1957 Farmall Cub w/FH
1977 International Cub w/FH
1978 International Cub
1948 Farmall Super A
Circle of Safety: Y
Location: MD, Deep Creek Lake

Re: Generator

Postby Don McCombs » Wed Feb 10, 2010 3:43 pm

Not a show tractor. Just a fresh paint job. :D
Don McCombs
MD, Deep Creek Lake

Image
Proud Member of Maryland Chapter 39

The best teachers are those who show you where to look, but don't tell you what to see.
A. K. Trenfor

User avatar
Bigdog
Team Cub Mentor
Team Cub Mentor
Posts: 24144
Joined: Sun Feb 02, 2003 12:50 pm
Zip Code: 43113
Circle of Safety: Y
Location: OH, Circleville
Contact:

Re: Generator

Postby Bigdog » Wed Feb 10, 2010 3:45 pm

One problem with wiring the lights from the dropping resistor for the coil. The amount of voltage dropped by the resistor is dependent on the current flow through it. With lights in the circuit the voltage drop across the resistor is going to change significantly. Additionally a 10 or 12 watt resistor that would function well for the coil circuit will not handle the load requirements for a lighting circuit.
Bigdog
If you can't fix it with a hammer, you've got an electrical problem.

My wife says I don't listen to her. - - - - - - - - Or something like that!

Image

http://www.cubtug.com

User avatar
SONNY
10+ Years
10+ Years
Posts: 4107
Joined: Thu Nov 09, 2006 11:26 pm
Zip Code: 61722

Re: Generator

Postby SONNY » Wed Feb 10, 2010 8:31 pm

Dan! if you feel comfortable at taking it apart, do so and clean everything up good ,might just be dirty armature and or brushes.---you could get lucky an only need new brushes and clean the armature with a long strip of emery cloth, (sandpaper will work, BUT not recommended ).
First check for output, you might even have to file the regulator points.---thats where I have the most trouble with the 6-v systems, they get dirty and points /armature get black(glazed over/corroded).
You can always go a different route if you cant get this one to work! thanks; sonny


Return to “Farmall A, Super A, AV, 100, 130 & 140”

Who is online

Users browsing this forum: No registered users and 12 guests