This site uses cookies to maintain login information on FarmallCub.Com. Click the X in the banner upper right corner to close this notice. For more information on our privacy policy, visit this link:
Privacy Policy

NEW REGISTERED MEMBERS: Be sure to check your SPAM/JUNK folders for the activation email.

1947 Cub 6 Volt and 12 Volt Quandary

The Cub Club -- Questions and answers to all of your Cub related issues.
Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
User avatar
jpate831
10+ Years
10+ Years
Posts: 83
Joined: Sun Jun 27, 2010 7:54 pm
Zip Code: 37172
Tractors Owned: 1947 Farmall Cub
1949 Massey-Harris Pony
1957 Allis Chalmers D14
1971 Sears SS14

1947 Cub 6 Volt and 12 Volt Quandary

Postby jpate831 » Sun Jun 27, 2010 8:32 pm

Hello Everyone.

I've been restoring a 1947 Farmall Cub in my spare time over the past 2 or 3 years. It was running fine before I started the restoration, but it didn't have enough paint on it to fill a thimble. I'm happy to say that this weekend I'm far enough along that I had the privilege of starting it up once again for the first time since I began the project. I hope to have it finished in time for the Adams TN show in July.

While I was putting a new wiring harness on it I discovered that there's a mixed bag of 6 and 12 volt components on the tractor. The battery is a 12 volt, and apparently the coil is as well, because it starts and runs good. It has a distributor instead of a magneto. The generator is a 6-volt according to the model number, and I'm sure the starter is too, based on how fast it spins when I start it. The ammeter shows a small amount of charge when I rev the engine up to about 1/2 or more throttle, and if I turn the light switch to the high charge position, the ammeter jumps up another notch. It seems to be charging, but I'm sure a 6 volt generator can't support a 12 volt battery. I'm guessing the light switch itself is also the 6-volt variety. It looks old enough to be original equipment. I don't know if the lights are 6 or 12-volt. I've never seen them burn yet, but the bulbs look fairly new. The tractor is still wired for positive ground. I understand from what I've read that the true 12-volt Cubs were negative ground.

What is the process for converting a Cub over from 6 to 12 volts completely?
Given my situation, what's the best thing to do?
Should I look for a 12 volt generator? Is there such a thing for the cub, or is it an alternator at that point?
If I get a generator, what else will I need to change?
Would it be better to stick with what I have now, and just charge the battery every once in a while?

Thanks.
Jamie

SPONSOR AD

Sponsor



Sponsor
 

User avatar
Bigdog
Team Cub Mentor
Team Cub Mentor
Posts: 24144
Joined: Sun Feb 02, 2003 12:50 pm
Zip Code: 43113
Circle of Safety: Y
Location: OH, Circleville
Contact:

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby Bigdog » Sun Jun 27, 2010 8:52 pm

Jamie - frankly there's not much point in converting to 12 volts if you are wanting to keep a generator. One of the main reasons for converting to 12 volts is the reliability and economics of using an alternator.
The conversion can be accomplished by installing a 12 volt coil (which you may already have) and switching the headlight and taillight bulbs to 12 volt. You can keep the 6 volt starter.
Install an alternator and you are ready to go. If you use a generator you will need a 12 volt generator and voltage regulator which are the weak link in either a 6 or 12 volt system.
You are correct that most 12 volt systems are negative ground and if you switch yours to negative ground you will need to reverse the leads on the ammeter.
Bigdog
If you can't fix it with a hammer, you've got an electrical problem.

My wife says I don't listen to her. - - - - - - - - Or something like that!

Image

http://www.cubtug.com

User avatar
Barnyard
Team Cub
Team Cub
Posts: 24240
Joined: Tue Aug 07, 2007 3:39 pm
Zip Code: 45030
Tractors Owned: At This Time
40 Farmall Cubs (Round Hood)
2 Farmall Cub (Square Hood)
2 IH Cubs (Square Hood)
5 Lo-Boys (Round Hood)
2 Lo-Boys (Square Hood)
2 Farmall 404's
1 Farmall H
1 Ferguson 20
1 Cub Cadet 125
1 Kubota B-7100
Circle of Safety: Y
Location: OH, New Haven (Hamilton County)
Contact:

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby Barnyard » Sun Jun 27, 2010 8:59 pm

Jamie, welcome to the forum. You're in good hands with the folks here. There isn't a question they can't answer, at least Cub related ones.

As for the distributor, you will be fine with that no matter if you go with 6v or 12v.
Last edited by Barnyard on Sun Jun 27, 2010 9:45 pm, edited 1 time in total.
There are two ways to get enough Cubs. One is to continue to accumulate more and more. The other is to desire less.

Circle of Safety

User avatar
challenger
10+ Years
10+ Years
Posts: 1087
Joined: Sun Apr 18, 2010 6:22 am
Zip Code: 21742
Tractors Owned: 1955 F Cub (2)
1952 F Cub
1948 F Cub
2155 JD
216 JD
Circle of Safety: Y
Location: Hagerstown MD

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby challenger » Sun Jun 27, 2010 9:06 pm

Jamie,

Why don't you check to see if you have a 12 volt generator. Ground the field on the generator and take a voltage reading on your armature output terminal to see whether you are at or over 12 volts.

User avatar
Rudi
Cub Pro
Cub Pro
Posts: 28706
Joined: Sun Feb 02, 2003 8:37 pm
Zip Code: E1A7J3
Skype Name: R.H. "Rudi" Saueracker, SSM
Tractors Owned: 1947 Cub "Granny"
1948 Cub "Ellie-Mae"
1968 Cub Lo-Boy
Dad's Putt-Putt
IH 129 CC
McCormick 100 Manure Spreader
McCormick 100-H Manure Spreader
Post Hole Digger
M-H #1 Potato Digger
Circle of Safety: Y
Twitter ID: Rudi Saueracker, SSM
Location: NB Dieppe, Canada
Contact:

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby Rudi » Sun Jun 27, 2010 9:08 pm

Jamie:

Image to the Farmallcub.com :big smile: Forum Family. And you have come to the right place for all things Cub related. If you click on the Site Rules, Regulations, & Important Information, it will point you to :arrow: the Welcome Wagon wherein you will find links to many useful sites and topics. One of which is the Cub Manual Server. You may also wish to check out the CubFests and Gatherings Calendar 2010 to find a gathering of fellow members where Cubs, Friends and a good time is shared by all. Enjoy!.


BD has pretty well answered your questions so there isn't much to add aside from preferences I guess. One other choice is to return the Cub to 6 volt positive ground status. You already have all of the necessary ingredients - (unless there is an external ballast resistor or the coil has an internal resistor - the coil may actually be 6 volt) and there will not be the worry about the genny being able to sustain the battery. Many PO's have simply installed a 12 volt battery in a Battery Ignition system without any other changes. Yours may indeed be this way as well. If you are not going to go to an alternator, then reverting to 6 volt may be just as easy to do.

If you indeed have a 12 volt coil, 6 volt coils are rather inexpensive at NAPA and easily substituted. If you are not going to convert to the alternator, IMHO, I would set it back up as a 6 volt positive ground system.
Confusion breeds Discussion which breeds Knowledge which breeds Confidence which breeds Friendship


User avatar
dgrapes59
10+ Years
10+ Years
Posts: 3726
Joined: Sun Jul 13, 2008 10:05 pm
Zip Code: 45067
Tractors Owned: 1951 Cub, 2-1955 Loboy w FH, a few plows, discs, mowers, blades, carrier & such
Several '61 CC Originals, Cub Cadet 100, several 102's & 122's, 124, various CC options & implements, #1Trailer, 1963 Springfield, JD 770, Ford 8N
Circle of Safety: Y
Location: OH, Trenton

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby dgrapes59 » Sun Jun 27, 2010 9:46 pm

Jamie,

Welcome to the Forum! You do know it's manditory to post some progress pictures... well not manditory but encouraged.. :lol:

It looks like you are in good hands and well on your way to the show in July!

Good luck,
David

User avatar
jpate831
10+ Years
10+ Years
Posts: 83
Joined: Sun Jun 27, 2010 7:54 pm
Zip Code: 37172
Tractors Owned: 1947 Farmall Cub
1949 Massey-Harris Pony
1957 Allis Chalmers D14
1971 Sears SS14

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby jpate831 » Sun Jun 27, 2010 10:49 pm

Thanks for the quick feedback guys.

The model number on my generator matches one of those referenced in the I&T shop manual, and the manual says it's a 6-volt generator. I'll put the voltmeter on it and make sure nothing's been changed there.

If I did revert back to a 6 volt battery, would I have to change the points or anything about the distributor?

If the coil happens to be a 6 volt coil, will having a 12 volt battery in the system damage it in any way?

Thanks again, guys.
Jamie

Gary Dotson
Team Cub Mentor
Team Cub Mentor
Posts: 5618
Joined: Thu Aug 03, 2006 6:20 am
Zip Code: 43358
Tractors Owned: 48 Cub Diesel (Cubota)
53 Cockshutt 20 restored (Shooter)
52 Cockshutt 20 unrestored
47 Leader "B" (Herckie)
49 Leader "D" (Princess)
49 Leader "D" very rough
48 Leader "D" unrestored
Kubota B6200E
Kubota B6200HST
Kubota B8200HST-D
Circle of Safety: Y
Location: OH West Mansfield

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby Gary Dotson » Mon Jun 28, 2010 4:36 am

Hi Jamie, welcome to the forum.
The distributor internals are the same, regardless of voltage or polarity. If the coil is a 6v. you will need a ballast resistor in series to the coil. Yes, 12 volts on a 6 volt coil will eventually fry the coil and/or the points.

User avatar
Bus Driver
10+ Years
10+ Years
Posts: 2917
Joined: Sat Feb 11, 2006 5:26 pm
Location: NC

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby Bus Driver » Mon Jun 28, 2010 6:32 am

Cub electrical systems, if so equipped, were originally 6 volt until the change to 12 volts during the 1964 model year. Alternators were first original on Cubs in late 1976. Delco 6 volt generators have black background on the ID tag, 12 volt models are red.
Luck favors those who are prepared

Eugene
Team Cub Mentor
Team Cub Mentor
Posts: 20344
Joined: Fri Jul 02, 2004 9:52 pm
Zip Code: 65051
Circle of Safety: Y
Location: Mo. Linn

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby Eugene » Mon Jun 28, 2010 6:47 am

jpate831 wrote:1947 Farmall Cub. The battery is a 12 volt. The generator is a 6-volt according to the model number. The ammeter shows a small amount of charge when I rev the engine up to about 1/2 or more throttle, and if I turn the light switch to the high charge position, the ammeter jumps up another notch.
Welcome.

Your charging system is working as it is supposed to. If the tractor were mine - I would leave things as they currently are until the charging system failed.

Engine running, amp meter showing charge. Volt meter across battery terminals will show generator voltage output.

User avatar
Boss Hog
Cub Pro
Cub Pro
Posts: 10290
Joined: Mon Oct 24, 2005 8:35 pm
Zip Code: 23962
eBay ID: dmb2613
Circle of Safety: Y
Location: VA. Randolph

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby Boss Hog » Mon Jun 28, 2010 8:01 am

Bus Driver wrote:Cub electrical systems, if so equipped, were originally 6 volt until the change to 12 volts during the 1964 model year. Alternators were first original on Cubs in late 1976. Delco 6 volt generators have black background on the ID tag, 12 volt models are red.


Alternators were mid 1975 I believe


Boss
IN GOD WE TRUST
All others pay cash
Boss Hog
Power corrupts; absolute power corrupts absolutely byJohn Emerich Edward Dalberg

User avatar
Rudi
Cub Pro
Cub Pro
Posts: 28706
Joined: Sun Feb 02, 2003 8:37 pm
Zip Code: E1A7J3
Skype Name: R.H. "Rudi" Saueracker, SSM
Tractors Owned: 1947 Cub "Granny"
1948 Cub "Ellie-Mae"
1968 Cub Lo-Boy
Dad's Putt-Putt
IH 129 CC
McCormick 100 Manure Spreader
McCormick 100-H Manure Spreader
Post Hole Digger
M-H #1 Potato Digger
Circle of Safety: Y
Twitter ID: Rudi Saueracker, SSM
Location: NB Dieppe, Canada
Contact:

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby Rudi » Mon Jun 28, 2010 9:22 am

jpate831 wrote:Thanks for the quick feedback guys.

The model number on my generator matches one of those referenced in the I&T shop manual, and the manual says it's a 6-volt generator. I'll put the voltmeter on it and make sure nothing's been changed there. So, you have everything needed to put the 6 volt batter back in. Plus.. if you get a Group 1 6 volt, it should fit right in your battery box :!: :D

If I did revert back to a 6 volt battery, would I have to change the points or anything about the distributor? Nope

If the coil happens to be a 6 volt coil, will having a 12 volt battery in the system damage it in any way? Yup.. in time it will fry the coil

Thanks again, guys.
Jamie


Also, as Gary said, if you have the 6 volt coil you will need to add an external ballast resistor to prevent frying the coil. Right now it is probably simpler and cheaper to just pop in the 6 volt battery. Let us know what you decide to do. And don't forget Image
Confusion breeds Discussion which breeds Knowledge which breeds Confidence which breeds Friendship


User avatar
Bill V in Md
10+ Years
10+ Years
Posts: 1111
Joined: Sun Feb 02, 2003 6:51 pm
Zip Code: 21228
Tractors Owned: 1948 Farmall Cub
LT1045 Cub Cadet
Circle of Safety: Y
Location: MD, Catonsville
Contact:

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby Bill V in Md » Mon Jun 28, 2010 9:48 am

Hello Jamie,

Welcome to the forum. I noticed your zip code and it brought back old memories. My family had a tobacco farm there for several years, and that is where I grew up. Good luck with your '47 Cub.
Bill VanHooser
Cub 54 Blade, Cub 193 Moldboard Plow, Cub 28A Disc Harrow
Circle of Safety

User avatar
BIGHOSS
Cub Pro
Cub Pro
Posts: 1741
Joined: Tue Jul 18, 2006 9:55 pm
Zip Code: 37087
Tractors Owned: 1947 Cub S/N 9216
w/ C-22 Mower

1974 Cub S/N 244814
w/59 Woods Mower

Ford 3000 Gas S/N C375091 w/Bushhog QT2345 Loader & 6' Squealer Bushhog
and a Palomino Mare named GIGI
Circle of Safety: Y
Location: TN, Lebanon

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby BIGHOSS » Mon Jun 28, 2010 10:31 am

Jamie
We may be neighbors. I am zip code 37087. If so, we need to meet.
"Courage is being scared to death-but saddling up anyway".......John Wayne

bythepond88
10+ Years
10+ Years
Posts: 1421
Joined: Sun Apr 30, 2006 2:54 pm
Zip Code: 60073
Circle of Safety: Y
Location: IL, Round Lake Heights

Re: 1947 Cub 6 Volt and 12 Volt Quandary

Postby bythepond88 » Mon Jun 28, 2010 5:18 pm

Jamie, if asked, I'd vote for going back to 6v. Most of the reasons I've seen for converting to 12v are that either the starter or the generator failed, and conversion was less expensive. Are there any numbers on the coil that you might be able to cross-reference to see if it's 6v or 12v?

As for NAPA having inexpensive coils, that isnt' the case where I live (they're $45 for the Echlin, $25 for the "cheap" one). However, Autozone does have them for about $17. They may not know that a 6v coil exists, but tell them the part number is C809. My local Autozone even had it in stock.
Michael Cummings
Eddie - a 1959 International Lo-Boy named after my father in law, who who bought her new.


Return to “Farmall Cub”

Who is online