Postby Pony Master » Tue Oct 12, 2010 2:02 pm

After getting the 100 running real nice I thought I was going to move on to the hydraulic lift, but after a few trial runs I noticed the battery seems to always be low. I put the meter on it, and no charge. First thing I decided to do is to clean the connections. Some were pretty bad, so I have to stop and pick up some properly sized ring terminals on my way to work. Then I noticed there was a ring terminal on the terminal on the rear of the Voltage Regulator, but no wire. After looking through a couple of my other manuals (no manual for a 100 yet) I am under the impression that it should be a ground. Is that the case? If not, what color of wire goes there? I have an extra aqua-greenish-blueish- wire that seems to go nowhere, I assume it goes to my non functioning headlights?
1947 Circle Cub, 193, 189
1954 Cub w/FH, IH100, 194, F11
1956 Cub Loboy w/FH and 194
1960 Cub Loboy w/FH and L-54
1953 Super A, 2 seater B, Avery V, Avery A, JD M, MH Pony, Leader D, Allis Chalmers C, and my Great Grandpa's ZA Minneapolis Moline.
User avatar
Pony Master
5+ Years
5+ Years
 
Posts: 3027
Joined: Thu Nov 15, 2007 10:39 am
Location: IL, Greenville
Zip Code: 62253
Circle of Safety Award
Circle of Safety: Y

Re: 100 wiring question

Postby Eugene » Tue Oct 12, 2010 3:30 pm

What is the letter under the regulator terminal? If the leter is an "L", not a ground.

http://www.cngco.com/

Go to Cub Cadet, Parts look up. There is a wiring diagram the 102.
I have an excuse. CRS.
Eugene
Team Cub Mentor
Team Cub Mentor
 
Posts: 12612
Joined: Fri Jul 02, 2004 9:52 pm
Location: Mo. Linn
Zip Code: 65051
Circle of Safety Award
Circle of Safety: Y

Re: 100 wiring question

Postby Paul B » Tue Oct 12, 2010 7:28 pm

If the 100 has the correct voltage regulator on it, that terminal is for the GEN. One side of the VR should have F or FLD, Bat, and L or Load. The other side or bottom should had a Gen terminal, and that bluish/greenish wire connects to that terminal and the other end connects to starter/generator "A" terminal.. The correct VR is grounded thru the VR mounts and does not have a ground terminal. The wire colors are:
VR Gen to generator A, Light blue
Generator A to starter button, Red
VR "F" to generator F, Yellow
VR Bat to stsrter button, Gray
VR "L" to ignition switch, Light Green
Ignition Sw to coil +, Black
Coil - to points, Black
Condenser to coil -.

Some other VR's do have a bottom side GRN or Ground terminal, but those do not have a "L" terminal.
Paul B
Team Cub Guide
Team Cub Guide
 
Posts: 2338
Joined: Sat Apr 10, 2004 6:12 pm
Location: KY, Louisville
Zip Code: 40218
Circle of Safety Award
Circle of Safety: Y

Re: 100 wiring question

Postby Eugene » Tue Oct 12, 2010 8:24 pm

I have an excuse. CRS.