Many of the radiators I determined to have caused overheating had accumulated huge amounts of debris and field dust turned to dried mud due to areas of damaged cooling fins on the fan side of the radiator.
The cooling fins soldered to the tubes dissipate heat just like the cooling fins on a small engine requiring them to be clean and have airflow along them to be efficient.
When these fan-side fins are bent over, not only is airflow reduced but they also trap debris and dust which fill the core from the inside out, further impeding airflow through the core.
Remember the dirt that collects in the air cleaner cup was also drawn from the same dust cloud inhaled by the fan, whether it passed through or became lodged depends on cooling fin condition.
Damage to the fan side of the radiator is most often caused while changing belts. Before performing mechanical work near the radiator, cut a piece of cardboard to cover the core to ensure knuckles, belts or wrenches don't flatten the fragile fins.
If fins are found to be damaged, obtain a fin straightening tool or other suitable device to correct the misaligned fins. With time and patience, you can transform flattened fins to near original alignment and spacing. The straightening tool does a nice job but you must start the straightening process one fin at a time before the tool will dig in.
If you use compressed air, it is better directed from the fan side pushing the crud out the way it went in. Unless you are positive the cooling fins are straight on the inside, avoid air or water from the front as the debris has no where to go and will only pack tighter in the damaged areas further reducing radiator efficiency.
Sometimes the simplest causes of overheating are overlooked and not addressed because they are not in plain sight.
This site uses cookies to maintain login information on FarmallCub.Com. Click the X in the banner upper right corner to close this notice. For more information on our privacy policy, visit this link: Privacy Policy
NEW REGISTERED MEMBERS: Be sure to check your SPAM/JUNK folders for the activation email.
Overheating, Radiator Cooling Fins
Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
-
- 10+ Years
- Posts: 438
- Joined: Tue Aug 07, 2012 1:37 am
- Zip Code: 44134
- Tractors Owned: 1949 & 1951 Farmall Cubs
Several Snapper Garden Tractors - Circle of Safety: Y
- Location: Southern Suburbs of Cleveland, Ohio
Overheating, Radiator Cooling Fins
- Attachments
-
- 1351525096-picsay.jpg (35.83 KiB) Viewed 314 times
"HAVE ALL YOUR DELIVERIES MADE BY UNION DRIVERS"
-
- 10+ Years
- Posts: 228
- Joined: Sat May 03, 2008 3:26 pm
Re: Overheating, Radiator Cooling Fins
LAZY UNION DRIVER
GOOD READ-----WELL WRITTEN
I MIGHT SAY I HAVE MADE A COPPER TUBE WITH A .060"" HOLE IN IT TO PUT WATER INTO EACH FIN ( +/- )
WORKS GOOD-----I USE A LOLLY POP STICK TO STRAIGHTEN OUT FIN'S-----BUT YOUR WAY IS BETTER------
GOOD LUCK
LOMBARD-------SC------
GOOD READ-----WELL WRITTEN
I MIGHT SAY I HAVE MADE A COPPER TUBE WITH A .060"" HOLE IN IT TO PUT WATER INTO EACH FIN ( +/- )
WORKS GOOD-----I USE A LOLLY POP STICK TO STRAIGHTEN OUT FIN'S-----BUT YOUR WAY IS BETTER------
GOOD LUCK
LOMBARD-------SC------