Postby torchred89 » Wed Mar 27, 2013 6:26 pm

The two wires that go to the Amp guage. The Amp guage has + & - Which on goes where. Ammeter to starter is that + or minus. and the ammeter to Regulator.

Thanks
This is my new hobby!

SPONSOR AD

Sponsor



Sponsor
 

User avatar
Mike in Louisiana
10+ Years
10+ Years
Posts: 7811
Joined: Tue Feb 15, 2005 10:10 am
Zip Code: 71023
Circle of Safety: Y
Location: LA, Doyline

Re: Wireing harness

Postby Mike in Louisiana » Wed Mar 27, 2013 6:40 pm

Tell us is your battery hooked up positive to ground or negitive to ground
1975 cub (LouAnn) serial # 245946, 1941 John Deere Model H

Good judgment comes from experience,
and a lot of that comes from bad judgment. Will Rogers

torchred89
10+ Years
10+ Years
Posts: 347
Joined: Wed Mar 06, 2013 12:20 pm
Zip Code: 20164
Tractors Owned: 1951 Farmall cub
Contact:

Re: Wireing harness

Postby torchred89 » Wed Mar 27, 2013 7:09 pm

Mike in Louisiana wrote:Tell us is your battery hooked up positive to ground or negitive to ground

Yes Postive ground

User avatar
clodhopper
10+ Years
10+ Years
Posts: 807
Joined: Sat May 07, 2011 8:20 pm
Zip Code: 27526
Tractors Owned: 1950 Cub Demo
1978 Cub Cadet 1650
cub 193 plow
cub 174 planter
cub sidedresser
cub 144 cultivator
cadet 50C deck
Circle of Safety: Y

Re: Wireing harness

Postby clodhopper » Wed Mar 27, 2013 7:29 pm

Are you sure its an ammeter? It should not be polarity specific...

tst
10+ Years
10+ Years
Posts: 5189
Joined: Tue Jan 12, 2010 2:08 pm
Zip Code: 12514
Circle of Safety: Y

Re: Wireing harness

Postby tst » Wed Mar 27, 2013 8:07 pm

ampmeters are marked, you have a 50/50 chance, when the wires are hooked with a draw on the system it should show on the discharge side, if it shows on the positive side its hooked up backwards, it won't hurt anything if its hooked backwards
tim

User avatar
twotone
10+ Years
10+ Years
Posts: 1189
Joined: Sat May 14, 2011 6:09 pm
Zip Code: 15132
Tractors Owned: 53 F Cub
73 F Cub
53 Super A With Snow/Grader Blade
193 Plow With Colter And Jointer
144 Cultivators
22 Mower
Circle of Safety: Y
Location: Versailles,Pa.

Re: Wireing harness

Postby twotone » Thu Mar 28, 2013 5:39 am

The wiring diagram shows the BAT on voltage regulator to POS on amp meter, and NEG on amp meter to ign switch. I never paid any attention as to how mine is hooked up, but on mine, Bat on VR is hooked to the terminal on the outboard side of guage.


Tom
Know Your Cub, And Your Cub Will Know You.

Tom

Jim Becker
Team Cub
Team Cub
Posts: 17241
Joined: Sun Feb 02, 2003 2:59 pm
Zip Code: 55319
Circle of Safety: Y
Location: MN

Re: Wireing harness

Postby Jim Becker » Thu Mar 28, 2013 8:52 am

twotone wrote:The wiring diagram shows the BAT on voltage regulator to POS on amp meter, and NEG on amp meter to ign switch. I never paid any attention as to how mine is hooked up, but on mine, Bat on VR is hooked to the terminal on the outboard side of guage.


Tom

I assume you intended to say "starter switch". If the ignition switch is fed directly from an ammeter lug, it should be connected to the same side as the lead from the VR. I'm pretty sure they would go on the (+) lug of the ammeter.

When I reassemble the wiring, I put wires on the ammeter based on which way the wires seem to be bent. Then I turn something on to see which way the needle goes. That method doesn't work with a new wiring harness.

User avatar
twotone
10+ Years
10+ Years
Posts: 1189
Joined: Sat May 14, 2011 6:09 pm
Zip Code: 15132
Tractors Owned: 53 F Cub
73 F Cub
53 Super A With Snow/Grader Blade
193 Plow With Colter And Jointer
144 Cultivators
22 Mower
Circle of Safety: Y
Location: Versailles,Pa.

Re: Wireing harness

Postby twotone » Thu Mar 28, 2013 11:22 am

Good catch Jim. I was going by the diagram on Rudi's Blue Ribbon manual.


Tom
Know Your Cub, And Your Cub Will Know You.

Tom

User avatar
Buzzard Wing
Cub Pro
Cub Pro
Posts: 10540
Joined: Mon Aug 09, 2004 10:14 pm
Zip Code: 02840
Location: RI, Newport

Re: Wireing harness

Postby Buzzard Wing » Fri Mar 29, 2013 7:36 am

A bit tough to read, but the operator's manual has wiring diagrams.
1971 Cub (Rufus) 1950 Cub (Cathy) 1965 Lo Boy Fast Hitch (Nameless III) 1970 Cub 1000 Loader & Fast Hitch (Lee)

User avatar
Rudi
Cub Pro
Cub Pro
Posts: 28706
Joined: Sun Feb 02, 2003 8:37 pm
Zip Code: E1A7J3
Skype Name: R.H. "Rudi" Saueracker, SSM
Tractors Owned: 1947 Cub "Granny"
1948 Cub "Ellie-Mae"
1968 Cub Lo-Boy
Dad's Putt-Putt
IH 129 CC
McCormick 100 Manure Spreader
McCormick 100-H Manure Spreader
Post Hole Digger
M-H #1 Potato Digger
Circle of Safety: Y
Twitter ID: Rudi Saueracker, SSM
Location: NB Dieppe, Canada
Contact:

Re: Wireing harness

Postby Rudi » Fri Mar 29, 2013 10:25 am

Image

This is Bob Melville's schematic which is on the server as well.
Confusion breeds Discussion which breeds Knowledge which breeds Confidence which breeds Friendship


torchred89
10+ Years
10+ Years
Posts: 347
Joined: Wed Mar 06, 2013 12:20 pm
Zip Code: 20164
Tractors Owned: 1951 Farmall cub
Contact:

Re: Wireing harness

Postby torchred89 » Fri Mar 29, 2013 6:35 pm

tst wrote:ampmeters are marked, you have a 50/50 chance, when the wires are hooked with a draw on the system it should show on the discharge side, if it shows on the positive side its hooked up backwards, it won't hurt anything if its hooked backwards
tim

Yep! 50/50 chance. I hope I can get in there to change. Without taking hood off. I got the new wireing harness on and put the hood back on. Hooked up the battery and pulled the swich with the lights on and the guage went to the + Just my luck :mrgreen:

Jim Becker
Team Cub
Team Cub
Posts: 17241
Joined: Sun Feb 02, 2003 2:59 pm
Zip Code: 55319
Circle of Safety: Y
Location: MN

Re: Wireing harness

Postby Jim Becker » Fri Mar 29, 2013 6:58 pm

Jim Becker wrote:When I reassemble the wiring, I put wires on the ammeter based on which way the wires seem to be bent. Then I turn something on to see which way the needle goes.


torchred89 wrote:
tst wrote:ampmeters are marked, you have a 50/50 chance, when the wires are hooked with a draw on the system it should show on the discharge side, if it shows on the positive side its hooked up backwards, it won't hurt anything if its hooked backwards
tim

Yep! 50/50 chance. I hope I can get in there to change. Without taking hood off. I got the new wireing harness on and put the hood back on. Hooked up the battery and pulled the swich with the lights on and the guage went to the + Just my luck :mrgreen:


Oh yeah, I should have mentioned hook up the battery and turn the light switch before putting the hood back on.

Chet
10+ Years
10+ Years
Posts: 50
Joined: Sat Feb 23, 2013 8:31 am
Zip Code: 36441
Tractors Owned: Farmall Cub, "Susie-Q" 61617 1948 /Woods 42 Mower, Sickle Mower. 2 gang disc, cultivators
Farmall Cub, "Sadie", 1949 Block Casting 2-3-S Duplex planter,Fert Distr
FarmallCub "Charlene" 22312 1948 Disc Plow, Flail Mower, Grader Blade
Location: 1510 OLD ATMORE ROAD, FLOMATON, AL FLOMATON, ALABAMA

Re: Wireing harness

Postby Chet » Tue Apr 02, 2013 8:49 am

Ahoy RUDI..... I just found your post re: ELECTRIC SCHEMATIC which reflected a cutout relay vice a regulator..... now I can relate to this. My 1949 61617 cub has what appears to be a CUTOUT RELAY which I see from the schematic is hooked up different than a VR. I have not been able to get my generator to GEN. Perhaps this is why? I do have the L-H-D-B switch.
Thanks much, very much. The schematic is listed for FARMALL H/M. Does that matter? Chet sends

User avatar
Rudi
Cub Pro
Cub Pro
Posts: 28706
Joined: Sun Feb 02, 2003 8:37 pm
Zip Code: E1A7J3
Skype Name: R.H. "Rudi" Saueracker, SSM
Tractors Owned: 1947 Cub "Granny"
1948 Cub "Ellie-Mae"
1968 Cub Lo-Boy
Dad's Putt-Putt
IH 129 CC
McCormick 100 Manure Spreader
McCormick 100-H Manure Spreader
Post Hole Digger
M-H #1 Potato Digger
Circle of Safety: Y
Twitter ID: Rudi Saueracker, SSM
Location: NB Dieppe, Canada
Contact:

Re: Wireing harness

Postby Rudi » Tue Apr 02, 2013 9:25 am

Chet:

Chet wrote:The schematic is listed for FARMALL H/M. Does that matter?


Simple answer is nope, it doesn't.
Confusion breeds Discussion which breeds Knowledge which breeds Confidence which breeds Friendship