electrical problem-farmall HModerator: Team Cub
16 posts
• Page 1 of 2 • 1, 2
electrical problem-farmall Hhi folks-just need to know if there is any electrical whiz out there that can help-my ammeter started going negativ about 5 amps when the tractor was running-i replaced the generator which i think was original delco or close to it-kept the regulator-polarized as instructrd and ran it-still shows a neg 5 amps-any ideas or fixes out there?-thanks hank
sounds like the regulator is stuck. Ground the F terminal on the generator and see if it charges then. If it does, either replace the regulator or open it up and look for burned or sticking contacts.
Bigdog
If you can't fix it with a hammer, you've got an electrical problem. My wife says I don't listen to her. - - - - - - - - Or something like that! http://www.cubtug.com
farmall H electrical probhi BD-well i checked the wiring-looks fine-used ohmmeter to look for shorts-found none-regulator has clean points-one set closed -the other open-closed set shows a spark when i open them up-tried that before when running to see if i had a charge-it went more negative-nothing looks burned-what's next-maybe a new regulator?-thanks-hank
electrical problem on an Hhi BD-i put the meter on at rest-reads 6.05 volts -at 1/2 throttle or so it reads 6.01 volts-that tell you anything?-i was thinking i might need to take the generator and regulator to the shop and have it run up and checked out-possibly a lemon rebuilt??-let me know-i am going to alberta tomorrow for a few days-i'll contact you as soon as i get back-hank
henry I know this is off topic but you live in one beautiful part of the country in the finger lakes.
Bill Sorensen Bill
"Life's tough.It's even tougher if you're stupid." - John Wayne " We hang petty thieves and appoint the great ones to public office." - Aesop
Hank, I believe that is the next step. It wouldn't be the first bad rebuilt unit. Before you do that though, make sure your grounds are good.
Did you try the same test with the field terminal of the generator grounded? Bigdog
If you can't fix it with a hammer, you've got an electrical problem. My wife says I don't listen to her. - - - - - - - - Or something like that! http://www.cubtug.com
"The Constitution is not an instrument for the government
to restrain the people, it is an instrument for the people to restrain the government lest it come to dominate our lives and interests." Patrick Henry
h electrical probhi bd-no i didn't-youy mean check voltage running and ground the f terminal?
Yes, ground the F terminal on the generator and start it up. Check the voltage at half throttle or higher. If it's charging, it will read 7 volts or higher. This will tell you whether the regulator circuit or the generator circuit is the problem. Once you know that, we can proceed.
Bigdog
If you can't fix it with a hammer, you've got an electrical problem. My wife says I don't listen to her. - - - - - - - - Or something like that! http://www.cubtug.com
h electrical problemhi john-i printed yor chart but didn't get all the way to the bottom-maybe my printer is off-what does the box below #4 say after generator on the left and replace voltage on the right?-hank
h electrical problemhi BD-i'll try that f terminal thing this am-and john-when your chart says regulator base does it mean the case of the regulator?-thanks-hank
h electrical prob-hi BD-i grounded the f terminal-started it up-got 5.9 volts at the battery terminals-what next?-hank
h electric problemhi-i think the gen may not be working-i'll take it in today to have it checked-my luck with rebuilts has always been lousy-thanks-hank