48 cub ignition switch
Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
-
- 10+ Years
- Posts: 60
- Joined: Sat Apr 07, 2012 3:12 am
- Zip Code: 40508
48 cub ignition switch
i was hoping to turn the motor over today with the starter and it wouldnt. the wiring on the switch was in rough shape and so did the switch itself. it is one of those generic toggle switches with 2 prongs both prongs arre connected and it was rewired at sometime with a homemade harness. anyways i want to replace it with a more oem type push in and out switch. i am having difficulty deciding which one to buy it has a magneto and i noticed the magneto switch has one prong and the electric ignition has 2 prongs. it seems obvious to order the electric igntion switch with 2 prongs, but is there a difference other than the number of connectors? thanks
-
- 10+ Years
- Posts: 60
- Joined: Sat Apr 07, 2012 3:12 am
- Zip Code: 40508
Re: 48 cub ignition switch
oh and it was converted over to 12volts as it has an alternator and had a 12 volt battery on it. if that matters. thanks allot i cant wait for this tractor to run again with ya'lls help
-
- Team Cub Mentor
- Posts: 5618
- Joined: Thu Aug 03, 2006 6:20 am
- Zip Code: 43358
- Tractors Owned: 48 Cub Diesel (Cubota)
53 Cockshutt 20 restored (Shooter)
52 Cockshutt 20 unrestored
47 Leader "B" (Herckie)
49 Leader "D" (Princess)
49 Leader "D" very rough
48 Leader "D" unrestored
Kubota B6200E
Kubota B6200HST
Kubota B8200HST-D - Circle of Safety: Y
- Location: OH West Mansfield
Re: 48 cub ignition switch
If your mag is still original, with it's internal coil, you need the 1 terminal switch. If it's been converted to battery ignition, with an external coil, it will require the 2 terminal switch.
- Rick Spivey
- Cub Pro
- Posts: 2778
- Joined: Sun Jul 01, 2007 10:07 pm
- Zip Code: 29518
- Circle of Safety: Y
- Location: SC, Cades 29518
Re: 48 cub ignition switch
1990caprice wrote:i was hoping to turn the motor over today with the starter and it wouldnt. the wiring on the switch was in rough shape and so did the switch itself. it is one of those generic toggle switches with 2 prongs both prongs arre connected and it was rewired at sometime with a homemade harness.
Just to be clear, that switch has nothing to do with the starter turning over. If two prong with battery ignition, it allows current to flow to the coil. If one prong with magneto, it allows you to ground out the points, shutting down the tractor. So it controls whether the tractor will run or not, but nothing about the starter turning over.
I hope that was helpful.
Rick Spivey
'52 Cub ("Great Personality") 148xxx
'48 Cub with FH ("Gunny Cub") 38xxx
'57 Lambretta (a slow work in progress)
'74 Triumph TR6 (Mama's toy)
'52 Cub ("Great Personality") 148xxx
'48 Cub with FH ("Gunny Cub") 38xxx
'57 Lambretta (a slow work in progress)
'74 Triumph TR6 (Mama's toy)
-
- 10+ Years
- Posts: 3369
- Joined: Mon Feb 17, 2003 8:48 pm
- Zip Code: 28081
- Circle of Safety: Y
- Location: NC, Kannapolis
Re: 48 cub ignition switch
If you can't find a one terminal switch, could you not use a two terminal switch with one terminal to mag and the other to ground?
"I'd rather be a mechanic in the shop"- Henry Ford
252646 & 221525. 195897 (Gone, but not forgotten)
252646 & 221525. 195897 (Gone, but not forgotten)
- BIGHOSS
- Cub Pro
- Posts: 1741
- Joined: Tue Jul 18, 2006 9:55 pm
- Zip Code: 37087
- Tractors Owned: 1947 Cub S/N 9216
w/ C-22 Mower
1974 Cub S/N 244814
w/59 Woods Mower
Ford 3000 Gas S/N C375091 w/Bushhog QT2345 Loader & 6' Squealer Bushhog
and a Palomino Mare named GIGI - Circle of Safety: Y
- Location: TN, Lebanon
Re: 48 cub ignition switch
Yes, that will work, but it messes with your mind. Because, you are pulling it out to stop and pushing it in to start.
"Courage is being scared to death-but saddling up anyway".......John Wayne
-
- 10+ Years
- Posts: 60
- Joined: Sat Apr 07, 2012 3:12 am
- Zip Code: 40508
Re: 48 cub ignition switch
it does have an external coil so 2 prong it is. the battery connections were also pretty bad so that probably had allot to do with the starter not engaging. on old gm starters with the 2 connectors i know you could jump the starter with a screw driver by touching the studs the starting system connects to. i am just getting at is there any way to test a starter? thanks
-
- 10+ Years
- Posts: 3369
- Joined: Mon Feb 17, 2003 8:48 pm
- Zip Code: 28081
- Circle of Safety: Y
- Location: NC, Kannapolis
Re: 48 cub ignition switch
To test starter make sure tractor is in neutral. Hook jumper cables to known good battery, (12v) hook ground cable to bolt holding starter, touch positive to terminal on top of starter. If good, starter will turn. Did I mention make sure tractor is in neutral! Or you can take the starter off and do the same thing. Either way good idea to clean starter contacts and check continuity and resistance. BTW what kind of shape are the battery cables in, the problem may be there.
"I'd rather be a mechanic in the shop"- Henry Ford
252646 & 221525. 195897 (Gone, but not forgotten)
252646 & 221525. 195897 (Gone, but not forgotten)
-
- 10+ Years
- Posts: 60
- Joined: Sat Apr 07, 2012 3:12 am
- Zip Code: 40508
Re: 48 cub ignition switch
the battery cables may be the culprit the tractor sat half under a shed for 13 years. the back half was out in the elements and the battery was not covered the insulation on cables is cracked. so they need to be cleaned or more than likely replaced.i still want to check the starter. thanks allot
-
- 10+ Years
- Posts: 1421
- Joined: Sun Apr 30, 2006 2:54 pm
- Zip Code: 60073
- Circle of Safety: Y
- Location: IL, Round Lake Heights
Re: 48 cub ignition switch
Just to clarify what Danovercash posted, once you have clipped the jumper to the starter post, you will still have to push on the switch to get the power to the starter. If that doesn't get the starter moving, remove the switch from the starter and touch the positive cable to the contact on the starter itself. If that works then the switch is defective.
Michael Cummings
Eddie - a 1959 International Lo-Boy named after my father in law, who who bought her new.
Eddie - a 1959 International Lo-Boy named after my father in law, who who bought her new.
-
- 10+ Years
- Posts: 60
- Joined: Sat Apr 07, 2012 3:12 am
- Zip Code: 40508
Re: 48 cub ignition switch
well my starter is dead . guess i'll have to find anouther one. thanks for the help
-
- 10+ Years
- Posts: 3369
- Joined: Mon Feb 17, 2003 8:48 pm
- Zip Code: 28081
- Circle of Safety: Y
- Location: NC, Kannapolis
Re: 48 cub ignition switch
Send it to a good repair/rebuild shop. May just need brushes.
"I'd rather be a mechanic in the shop"- Henry Ford
252646 & 221525. 195897 (Gone, but not forgotten)
252646 & 221525. 195897 (Gone, but not forgotten)
-
- 10+ Years
- Posts: 1068
- Joined: Sat Dec 10, 2005 4:31 pm
- Zip Code: 66839
- Circle of Safety: Y
- Location: KS. Burlington
Re: 48 cub ignition switch
1990caprice wrote:i was hoping to turn the motor over today with the starter and it wouldnt. the wiring on the switch was in rough shape and so did the switch itself. it is one of those generic toggle switches with 2 prongs both prongs arre connected and it was rewired at sometime with a homemade harness. anyways i want to replace it with a more oem type push in and out switch. i am having difficulty deciding which one to buy it has a magneto and i noticed the magneto switch has one prong and the electric ignition has 2 prongs. it seems obvious to order the electric igntion switch with 2 prongs, but is there a difference other than the number of connectors? thanks
The one prong switch will only kill the mag. You will need another switch or something to keep the voltage from feeding through the alternator and coil when tractor is not running. Two different things. It can be done with one switch, but easier and less expensive with two switches.
-
- 10+ Years
- Posts: 60
- Joined: Sat Apr 07, 2012 3:12 am
- Zip Code: 40508
Re: 48 cub ignition switch
well i got a new switch. looking at a wiring schematic it shows the ammeter connected to one prong and the coil/ ballast resister connected to the other. Does it matter which prong is connected to the ammeter and which prong is connected to the coil? thanks allot!
- Rudi
- Cub Pro
- Posts: 28706
- Joined: Sun Feb 02, 2003 8:37 pm
- Zip Code: E1A7J3
- Skype Name: R.H. "Rudi" Saueracker, SSM
- Tractors Owned: 1947 Cub "Granny"
1948 Cub "Ellie-Mae"
1968 Cub Lo-Boy
Dad's Putt-Putt
IH 129 CC
McCormick 100 Manure Spreader
McCormick 100-H Manure Spreader
Post Hole Digger
M-H #1 Potato Digger - Circle of Safety: Y
- Twitter ID: Rudi Saueracker, SSM
- Location: NB Dieppe, Canada
- Contact:
Re: 48 cub ignition switch
David:
Does this help?
Does this help?
Confusion breeds Discussion which breeds Knowledge which breeds Confidence which breeds Friendship
Who is online
Users browsing this forum: Majestic-12 [Bot] and 28 guests