Positive / Negative Ground Re: Voltage Regulator

The Cub Club -- Questions and answers to all of your Cub related issues.
Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
User avatar
Connecticut Calvin
10+ Years
10+ Years
Posts: 142
Joined: Thu Aug 15, 2013 7:40 am
Zip Code: 06070
Tractors Owned: '54 Farmall Cub "Betty"
Location: Simsbury, Conn.
Contact:

Positive / Negative Ground Re: Voltage Regulator

Postby Connecticut Calvin » Mon Sep 23, 2013 12:00 pm

Hi fellas (And ladies? Hey why not? :D ): Seems quite a few threads comment on the idea that those that pull their battery out and put it back in with the terminals wired backwards is a common occurance. It also seems that the tractors normally start and charge fine and it's only pure happenstance that they notice the backwards configuration; typically when they see the ammeter showing discharge when it is in fact charging. :? Then they get all worried and come here and the pros say, "Hey, go get a :beer: and chill." lol So why is it that the tractor can charge the system and run normally with reversed polarity even when they have a voltage regulator that is for a "positive ground" electrical system? If the voltage regulator "didn't care" abut polarity, why are they labeled as if they are polarity sensitive?

I ask because my tractor is now positive ground but as some may recall from an earlier post that I have a funky 6 volt positive-ground voltage regulator that is making my 6 volt battery nearly 9 volts :shock:. The last thing I want is to damage my battery or worse, cause and explosion or fire. As always - :thanx:
She thinks my tractor's sexy...

SPONSOR AD

Sponsor



Sponsor
 

bythepond88
10+ Years
10+ Years
Posts: 1421
Joined: Sun Apr 30, 2006 2:54 pm
Zip Code: 60073
Circle of Safety: Y
Location: IL, Round Lake Heights

Re: Positive / Negative Ground Re: Voltage Regulator

Postby bythepond88 » Mon Sep 23, 2013 12:28 pm

Not sure about the theory behind it, but I do know that regulators (at least the 6v ones) need to be properly polarized to charge properly. These regulators can be polarized for either positive or negative earth. So maybe the label on the box merely indicates how the VR was polarized at the factory?
Michael Cummings
Eddie - a 1959 International Lo-Boy named after my father in law, who who bought her new.

User avatar
LeeC
10+ Years
10+ Years
Posts: 343
Joined: Fri Oct 31, 2008 2:07 pm
Zip Code: 22150
Tractors Owned: 2 1962 LoBoys
1 1964 LoBoy
1 1965 LoBoy
1 1966 LoBoy
Circle of Safety: Y
Location: Springfield, VA

Re: Positive / Negative Ground Re: Voltage Regulator

Postby LeeC » Mon Sep 23, 2013 3:22 pm

I believe it is the generator that gets polarized, not the regulator. I have no earthly idea why they specifically mark the mechanical relay used with the Cub as 6 volt positive as the polarity should make no difference and I have seen them run either way.
Circle of Safety

User avatar
Connecticut Calvin
10+ Years
10+ Years
Posts: 142
Joined: Thu Aug 15, 2013 7:40 am
Zip Code: 06070
Tractors Owned: '54 Farmall Cub "Betty"
Location: Simsbury, Conn.
Contact:

Re: Positive / Negative Ground Re: Voltage Regulator

Postby Connecticut Calvin » Mon Sep 23, 2013 3:29 pm

My voltage regulator on my '54 is presumably from an old Model A and not for the Cub. It is a 6V positive ground unit and the consensus is that it should still function for the Cub. It also has only two terminals on it and responses to earlier posts indicated the configuration means it is always at full charge. Presuming this unit will work even though the polarity is reversed, can it be adjusted somehow to reduce the charge rate? :?:

If anyone has any other ideas as to its polarity rating I'd love to hear (read? lol) your thoughts. It baffles my mind that they're listed as being for a certain polarity but work either way. :?
She thinks my tractor's sexy...

Eugene
Team Cub Mentor
Team Cub Mentor
Posts: 20344
Joined: Fri Jul 02, 2004 9:52 pm
Zip Code: 65051
Circle of Safety: Y
Location: Mo. Linn

Re: Positive / Negative Ground Re: Voltage Regulator

Postby Eugene » Mon Sep 23, 2013 4:28 pm

Your "voltage regulator" with two terminals would indicate that it's a cut out as opposed to a voltage regulator, which has at least 3 terminals.

It's quite possible that your "voltage regulator" cutout is polarity specific to activate the shunt winding (battery disconnect).

If you have a cut out, it was frequently used with a 3 brush generator. To adjust the voltage out put on a 3 brush generator you need to move the adjustable brush.
I have an excuse. CRS.

User avatar
Connecticut Calvin
10+ Years
10+ Years
Posts: 142
Joined: Thu Aug 15, 2013 7:40 am
Zip Code: 06070
Tractors Owned: '54 Farmall Cub "Betty"
Location: Simsbury, Conn.
Contact:

Re: Positive / Negative Ground Re: Voltage Regulator

Postby Connecticut Calvin » Mon Sep 23, 2013 5:38 pm

Eugene wrote:Your "voltage regulator" with two terminals would indicate that it's a cut out as opposed to a voltage regulator, which has at least 3 terminals.

It's quite possible that your "voltage regulator" cutout is polarity specific to activate the shunt winding (battery disconnect).

If you have a cut out, it was frequently used with a 3 brush generator. To adjust the voltage out put on a 3 brush generator you need to move the adjustable brush.


So am I correct that I'm not going to be able to run this tractor with negative ground if my cutout is in fact polarity sensitive? Even if I could adjust my generator the cutout will not function properly in this configuration, yes?
She thinks my tractor's sexy...

Eugene
Team Cub Mentor
Team Cub Mentor
Posts: 20344
Joined: Fri Jul 02, 2004 9:52 pm
Zip Code: 65051
Circle of Safety: Y
Location: Mo. Linn

Re: Positive / Negative Ground Re: Voltage Regulator

Postby Eugene » Mon Sep 23, 2013 6:11 pm

Connecticut Calvin wrote:So am I correct that I'm not going to be able to run this tractor with negative ground if my cutout is in fact polarity sensitive? Even if I could adjust my generator the cutout will not function properly in this configuration, yes?
I don't know and may be. I don't know how your "regulator" "cut out" is wired or which regulator/cut out you have, so I could look it up. I also do not know which generator you have. K.I.S.S. If the cut out/regulator says positive ground - make the battery positive ground.

Your original post said "regulator" and "nearly 9 volts". Determine the number of brushes in the generator. You need to reduce the generator output voltage by about 1 to 1.5 volts.
I have an excuse. CRS.

User avatar
Connecticut Calvin
10+ Years
10+ Years
Posts: 142
Joined: Thu Aug 15, 2013 7:40 am
Zip Code: 06070
Tractors Owned: '54 Farmall Cub "Betty"
Location: Simsbury, Conn.
Contact:

Re: Positive / Negative Ground Re: Voltage Regulator

Postby Connecticut Calvin » Mon Sep 23, 2013 7:16 pm

Eugene wrote: Your original post said "regulator" and "nearly 9 volts". Determine the number of brushes in the generator. You need to reduce the generator output voltage by about 1 to 1.5 volts.


Regulator / cutout, what do I know? :? In prior posts it seemed no one could pinpoint what I had either. But a cutout sure seems accurate. I really liked the idea of keeping the tractor negative ground but this no longer seems like an option. I have some higher priced LEDs that will blow with this kind of voltage and who knows what will happen to the battery. Looks like I'll have no choice but go back to positive ground and use standard incandescent bulbs. I'd rather not risk any damage to the tractor for a set of bulbs. I'll consider this topic a moot point. Thanks for guiding me to the light of reality! No pun intended. :D
She thinks my tractor's sexy...

Gary Dotson
Team Cub Mentor
Team Cub Mentor
Posts: 5618
Joined: Thu Aug 03, 2006 6:20 am
Zip Code: 43358
Tractors Owned: 48 Cub Diesel (Cubota)
53 Cockshutt 20 restored (Shooter)
52 Cockshutt 20 unrestored
47 Leader "B" (Herckie)
49 Leader "D" (Princess)
49 Leader "D" very rough
48 Leader "D" unrestored
Kubota B6200E
Kubota B6200HST
Kubota B8200HST-D
Circle of Safety: Y
Location: OH West Mansfield

Re: Positive / Negative Ground Re: Voltage Regulator

Postby Gary Dotson » Tue Sep 24, 2013 7:06 am

The neg./pos. designation on the regulator has to do with the dissimilar metals in the regulator contacts. The arm is a different alloy than the fixed contact to reduce contact arcing, those alloys will be positioned in one configuration for pos, ground and in the reversed config. for neg. ground. The regulator (or cutout) will function the same in either neg. or pos. ground but when a pos. ground unit is connected neg. ground it will have a shorter life span.
As to your overcharging, look again at what Eugene posted about the 3rd brush. That was the method of limiting generator output on earlier units.

Matt Kirsch
10+ Years
10+ Years
Posts: 4947
Joined: Tue Jun 08, 2004 3:04 pm
Zip Code: 14559
Circle of Safety: Y
Location: Rochester, NY

Re: Positive / Negative Ground Re: Voltage Regulator

Postby Matt Kirsch » Tue Sep 24, 2013 12:33 pm

That said, a "positive" regulator or cutout will work with negative ground, just maybe not as well, or not as long, as if it were wired properly. Maybe.

My theory on the whole thing is it's a little "subliminal message" to reassure people that they have the appropriate part, even though it doesn't make a hill of beans' difference one way or the other.

It's like the 6V vs. 12V "ballast resistor required" ignition coils. If you go to an auto parts store and ask for an ignition coil for a vehicle with a 12V ignition system from the 1960's, you will get a coil labeled "12V ballast resistor required." This 12V coil is no different from a 6V coil. It's just labeled 12V so people don't get confused.

User avatar
Connecticut Calvin
10+ Years
10+ Years
Posts: 142
Joined: Thu Aug 15, 2013 7:40 am
Zip Code: 06070
Tractors Owned: '54 Farmall Cub "Betty"
Location: Simsbury, Conn.
Contact:

Re: Positive / Negative Ground Re: Voltage Regulator

Postby Connecticut Calvin » Tue Sep 24, 2013 4:07 pm

Okay well ol' Betty is back to negative ground. :!: I switched the coil wires and the + wire is now going to the distributor cap, reversed the ammeter wires and reversed the battery cables. I'm getting about .25 amp charge at idle, .5 amp charge at mid throttle and a little over a single amp at full throttle. Let's hope this solves my issue. After an hour's use today and a few starts and stops my battery is holding steady at 6.75(ish) volts. Perhaps my cutout is OK and it just didn't like the way my wiring was done. Oh well, so long expensive LEDs. :idea: :idea: It was nice knowing you! :roll: Anyone want nice, unused 6v NEGATIVE GROUND LEDs for their machine PM me! I have 4! :D

All great input gents. Thank you. :worthy:
She thinks my tractor's sexy...

danovercash
10+ Years
10+ Years
Posts: 3369
Joined: Mon Feb 17, 2003 8:48 pm
Zip Code: 28081
Circle of Safety: Y
Location: NC, Kannapolis

Re: Positive / Negative Ground Re: Voltage Regulator

Postby danovercash » Tue Sep 24, 2013 6:05 pm

Put them in the classifieds with pictures!
"I'd rather be a mechanic in the shop"- Henry Ford

252646 & 221525. 195897 (Gone, but not forgotten)

User avatar
Connecticut Calvin
10+ Years
10+ Years
Posts: 142
Joined: Thu Aug 15, 2013 7:40 am
Zip Code: 06070
Tractors Owned: '54 Farmall Cub "Betty"
Location: Simsbury, Conn.
Contact:

Re: Positive / Negative Ground Re: Voltage Regulator

Postby Connecticut Calvin » Wed Sep 25, 2013 8:25 am

danovercash wrote:Put them in the classifieds with pictures!


Posted!
She thinks my tractor's sexy...