This site uses cookies to maintain login information on FarmallCub.Com. Click the X in the banner upper right corner to close this notice. For more information on our privacy policy, visit this link: Privacy Policy
NEW REGISTERED MEMBERS: Be sure to check your SPAM/JUNK folders for the activation email.
Bad Generator...
Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
-
- 10+ Years
- Posts: 160
- Joined: Wed Aug 07, 2013 10:09 am
- Zip Code: 14103
- Tractors Owned: 1955 farmall cub w/ fast hitch
Implements:
fast hitch moldboard plow
fast hitch disc harrow
front blade
Danco c-3 mower - Circle of Safety: Y
Bad Generator...
my cub is a 55 with original 6 volt positive ground setup. I just got through replacing the rat's nest of wiring that was there when I got it, and the ammeter shows discharge when running. I've gone through the troubleshooting chart that i've seen referenced here before, and i replaced the old regulator just for good measure, but it seems the generator is in fact the culprit. what are my options? I haven't seen any how-to on rebuilding a generator, is it something that an amateur should attempt?
-
- 10+ Years
Re: Bad Generator...
Check the voltage at the battery with the engine off then check the battery voltage with the engine running, was it more when running?
Not sure on the cub but on other 12v amp gauges I have seen in the past if you have the wires reversed at the gauge it reads backwards, meaning it will show discharge when its really charging.
voltage goes up when the engine running swap wires at the gauge?
Not sure on the cub but on other 12v amp gauges I have seen in the past if you have the wires reversed at the gauge it reads backwards, meaning it will show discharge when its really charging.
voltage goes up when the engine running swap wires at the gauge?
- Mike in Louisiana
- 10+ Years
- Posts: 7812
- Joined: Tue Feb 15, 2005 10:10 am
- Zip Code: 71023
- Circle of Safety: Y
- Location: LA, Doyline
Re: Bad Generator...
have you polarized it???????????????????
1975 cub (LouAnn) serial # 245946, 1941 John Deere Model H
Good judgment comes from experience,
and a lot of that comes from bad judgment. Will Rogers
Good judgment comes from experience,
and a lot of that comes from bad judgment. Will Rogers
-
- 10+ Years
- Posts: 160
- Joined: Wed Aug 07, 2013 10:09 am
- Zip Code: 14103
- Tractors Owned: 1955 farmall cub w/ fast hitch
Implements:
fast hitch moldboard plow
fast hitch disc harrow
front blade
Danco c-3 mower - Circle of Safety: Y
Re: Bad Generator...
I thought about that, but I think it's hooked up correctly. when i turn on the ignition switch (before the engine is turning) the ammeter drops like 1/4 inch to the left, and it stays about the same while the engine is running. I can't test it with the lights, since the bulbs are dead.. I'll double check with the volt meter though. thanks!
yes, I jumped the batt terminal to the gen terminal at the regulator and it gave one heck of a spark! that's all there is to it right?
Mike in Louisiana wrote:have you polarized it???????????????????
yes, I jumped the batt terminal to the gen terminal at the regulator and it gave one heck of a spark! that's all there is to it right?
- twotone
- 10+ Years
- Posts: 1189
- Joined: Sat May 14, 2011 6:09 pm
- Zip Code: 15132
- Tractors Owned: 53 F Cub
73 F Cub
53 Super A With Snow/Grader Blade
193 Plow With Colter And Jointer
144 Cultivators
22 Mower - Circle of Safety: Y
- Location: Versailles,Pa.
Re: Bad Generator...
Does the voltage regulator have a good ground? Run a jumper wire to test it.
Know Your Cub, And Your Cub Will Know You.
Tom
Tom
-
- Team Cub Mentor
- Posts: 20344
- Joined: Fri Jul 02, 2004 9:52 pm
- Zip Code: 65051
- Circle of Safety: Y
- Location: Mo. Linn
Re: Bad Generator...
The generator is not that hard to repair. But since you asked the question, my suggestion is to take the generator and regulator to a repair shop.Eoghan wrote: I haven't seen any how-to on rebuilding a generator, is it something that an amateur should attempt?
Well. Not knowing the cost of the generator repair and other repairs - - - I would have initially suggested a conversion to a 12 volt single wire alternator. - - - Much cheaper and more reliable.what are my options?
I have an excuse. CRS.
-
- 10+ Years
- Posts: 160
- Joined: Wed Aug 07, 2013 10:09 am
- Zip Code: 14103
- Tractors Owned: 1955 farmall cub w/ fast hitch
Implements:
fast hitch moldboard plow
fast hitch disc harrow
front blade
Danco c-3 mower - Circle of Safety: Y
Re: Bad Generator...
I cleaned up the ground when I replaced the regulator, and I tested it and it's good so that's not the prob.
despite my inexperience, I feel like i have very little to lose, so i'm going to crack open the generator and see what i'm working with. I did some reading and i think i have a basic understanding of the components and how they're supposed to work.
Speaking of which, this site as well as Rudy's manual site are such an amazing resource, I can't thank you guys enough for all the time you've put into it. I'm pretty new to working with cubs (and frankly engines in general), but with the forum search I can almost always find answers to my questions without even having to ask! Thanks to you guys these awesome little tractors are going to be around for a long time to come.
despite my inexperience, I feel like i have very little to lose, so i'm going to crack open the generator and see what i'm working with. I did some reading and i think i have a basic understanding of the components and how they're supposed to work.
Speaking of which, this site as well as Rudy's manual site are such an amazing resource, I can't thank you guys enough for all the time you've put into it. I'm pretty new to working with cubs (and frankly engines in general), but with the forum search I can almost always find answers to my questions without even having to ask! Thanks to you guys these awesome little tractors are going to be around for a long time to come.
-
- 10+ Years
- Posts: 160
- Joined: Wed Aug 07, 2013 10:09 am
- Zip Code: 14103
- Tractors Owned: 1955 farmall cub w/ fast hitch
Implements:
fast hitch moldboard plow
fast hitch disc harrow
front blade
Danco c-3 mower - Circle of Safety: Y
Re: Bad Generator...
Just read through this:
http://www.cleancomputes.com/Cub/Blue%2 ... trical.htm
and feeling much more confident.
http://www.cleancomputes.com/Cub/Blue%2 ... trical.htm
and feeling much more confident.
-
- 10+ Years
- Posts: 347
- Joined: Wed Mar 06, 2013 12:20 pm
- Zip Code: 20164
- Tractors Owned: 1951 Farmall cub
- Contact:
Re: Bad Generator...
I just had my generator rebuilt. They charged $125
-
- Cub Pro
- Posts: 7504
- Joined: Thu Aug 31, 2006 7:00 pm
- Zip Code: 02769
- Tractors Owned: 6"F" cubs
5 lo-boys
1 154
1 184
1 IH444
1 Oliver OC3 crawler
1 AC D10
1 IH 100 manure spreader
1 IH model B corn grinder
3 power units
cub demonstrator - Circle of Safety: Y
- Location: Ma. Rehoboth
Re: Bad Generator...
torchred89 wrote:I just had my generator rebuilt. They charged $125
Had one rebuilt, for a relative,about 2 years ago. Same price! Makes the 12 volt conversion, look good! New regulator, at that time, need replacing, again. (I suggested 12V, he wanted "original". )
Ed
-
- 10+ Years
- Posts: 160
- Joined: Wed Aug 07, 2013 10:09 am
- Zip Code: 14103
- Tractors Owned: 1955 farmall cub w/ fast hitch
Implements:
fast hitch moldboard plow
fast hitch disc harrow
front blade
Danco c-3 mower - Circle of Safety: Y
Re: Bad Generator...
problem solved!
The fault was with the regulator. The cutout must have been a little sticky because i had to rev the engine up to full rpms before it kicked in, but then when i throttled down it kept charging fine. The needle on the ammeter is very bouncy when charging, is that normal? I assume it's just the points of the relay opening and closing inside the regulator? The volt meter reads between 12 and 18 volts when running. I wish i had an analog tester, there's a lot of noise going on and the digital can't handle it.
I also see now what i did wrong in my diagnosis: when I bypassed the original regulator the ground was probably bad. then I shined it up when i put on the new regulator, and i never did the bypass test again.. so when it still didn't charge i assumed it was the generator. Next time I'll follow directions better!
I guess now i can put off rebuilding the generator, but I think i might actually open up the old regulator and clean it up since it's a much nicer old delco model compared to the new TSC chinese special I just put on. as for the 12 volt conversion, i have no ideological objections to changing from "original" but my wallet complains when i spend money that i don't need to. the gen rebuild kits i've seen on ebay are less than 20 bucks, and i think you can even get new field coils pretty cheap if they're dinged up. when it's damaged beyond a simple repair or i get tired of the hard cold starting, then I'll think about switching.
The fault was with the regulator. The cutout must have been a little sticky because i had to rev the engine up to full rpms before it kicked in, but then when i throttled down it kept charging fine. The needle on the ammeter is very bouncy when charging, is that normal? I assume it's just the points of the relay opening and closing inside the regulator? The volt meter reads between 12 and 18 volts when running. I wish i had an analog tester, there's a lot of noise going on and the digital can't handle it.
I also see now what i did wrong in my diagnosis: when I bypassed the original regulator the ground was probably bad. then I shined it up when i put on the new regulator, and i never did the bypass test again.. so when it still didn't charge i assumed it was the generator. Next time I'll follow directions better!
I guess now i can put off rebuilding the generator, but I think i might actually open up the old regulator and clean it up since it's a much nicer old delco model compared to the new TSC chinese special I just put on. as for the 12 volt conversion, i have no ideological objections to changing from "original" but my wallet complains when i spend money that i don't need to. the gen rebuild kits i've seen on ebay are less than 20 bucks, and i think you can even get new field coils pretty cheap if they're dinged up. when it's damaged beyond a simple repair or i get tired of the hard cold starting, then I'll think about switching.
-
- Team Cub Mentor
- Posts: 20344
- Joined: Fri Jul 02, 2004 9:52 pm
- Zip Code: 65051
- Circle of Safety: Y
- Location: Mo. Linn
Re: Bad Generator...
Brushes, bushing, and bearing for generators are available from auto parts stores. Cost of common repair parts, not very much.
I have an excuse. CRS.