I have talked with you guys many times in the past and I just can not seem to remember everything or things just stop working.
well I have a Farmall A with a Chrysler 6 volt generator/ hydraulic pump combo it was used to lif convertable tops. I actualy got it off a doodle bug and it works the hydrualics good.
Anyhow I took and put a 12 volt battery in the tractor and a 12 volt regulator. The tractor has a mag so I didn't need to worry about that.
when I hooked it all up I had the same problem as when I was trying to go 6 volt. I had to pull the reg cover and adjust the feild coil before it would charge. when it did charge I took a reading and the battery and it was 13.2-13.6 volts depending on engine speed. I figured that the old genny would work just fine to charge the battery????????
when I un-hooked the battery to put the battry box back in and went to hook it up it would not charge. This is getting me upset every time I get it charging either 6 volt or 12 volt it will work for a while then stop. my question is since i had to un-hook the battery do I need to re-adjust the feild coil now that it is hooked back up?
I have tried several new regulators and none of them work right out of the box. what do you think could be the problem?
I have it hooked up like this arm to gen, feild to feild. battery to positive on amp meter then other side to battery. I skipped the light switch since i do not have light on my tractor anyway. Is the any suggestions?
thanks
Chad
This site uses cookies to maintain login information on FarmallCub.Com. Click the X in the banner upper right corner to close this notice. For more information on our privacy policy, visit this link: Privacy Policy
NEW REGISTERED MEMBERS: Be sure to check your SPAM/JUNK folders for the activation email.
generator/regulator problems
Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
-
- 10+ Years
- Posts: 1080
- Joined: Mon Feb 03, 2003 1:15 pm
- Location: St. Charles, MI 48655
generator/regulator problems
"don't find fault, find a remedy"
1948 Cub, 1945 A, 1955 100
1948 Cub, 1945 A, 1955 100
-
- 10+ Years
- Posts: 7703
- Joined: Thu Aug 19, 2004 2:31 pm
- Zip Code: 10314
- Location: NY Staten Island & Franklin
Re: generator/regulator problems
Don't forget generators may need to be polorized after being disconnected from a battery.
Bill
"Life's tough.It's even tougher if you're stupid."
- John Wayne
" We hang petty thieves and appoint the great ones to public office."
- Aesop
"Life's tough.It's even tougher if you're stupid."
- John Wayne
" We hang petty thieves and appoint the great ones to public office."
- Aesop
-
- 10+ Years
- Posts: 219
- Joined: Thu Nov 12, 2009 1:36 pm
- Zip Code: 61272
- Tractors Owned: Tractors
1940s Allis Chalmers B
1966 140
Cars
1964 Cadillac
1955 R190 - Location: New Boston IL
Re: generator/regulator problems
beaconlight wrote:Don't forget generators may need to be polorized after being disconnected from a battery.
This is true, and also make sure that the ground connections for the regulators are very clean. I had a problem with mine where it had very dirty ground connections. Once this was cleaned up then things started to work fine. Setting the polarity is not difficult. On my super a you use a jumper wire and connect the bat and gen terminals on the voltage regulator. All you should have to do is a quick touch and it should be reset.
Jason
"Beauty through function and simplification."
"Raymond Lowey"
"Beauty through function and simplification."
"Raymond Lowey"
-
- 10+ Years
- Posts: 1080
- Joined: Mon Feb 03, 2003 1:15 pm
- Location: St. Charles, MI 48655
Re: generator/regulator problems
thanks for the help I did polarise it and I had cleaned up the grounds.
Chad
Chad
"don't find fault, find a remedy"
1948 Cub, 1945 A, 1955 100
1948 Cub, 1945 A, 1955 100
-
- 10+ Years
- Posts: 1080
- Joined: Mon Feb 03, 2003 1:15 pm
- Location: St. Charles, MI 48655
Re: generator/regulator problems
I got it! when I re-connected the battery I had to polarise it and I had to jumper the feild to ground then un hook it and everything is working.
"don't find fault, find a remedy"
1948 Cub, 1945 A, 1955 100
1948 Cub, 1945 A, 1955 100
-
- 10+ Years
- Posts: 7703
- Joined: Thu Aug 19, 2004 2:31 pm
- Zip Code: 10314
- Location: NY Staten Island & Franklin
Re: generator/regulator problems
Don't you just love it when a plan comes together.
Bill
"Life's tough.It's even tougher if you're stupid."
- John Wayne
" We hang petty thieves and appoint the great ones to public office."
- Aesop
"Life's tough.It's even tougher if you're stupid."
- John Wayne
" We hang petty thieves and appoint the great ones to public office."
- Aesop
-
- Similar Topics
- Replies
- Views
- Last post
-
-
Farmall Super A Voltage Regulator Problems
by dalton.scism » Tue Apr 19, 2022 7:35 am » in Farmall A, Super A, AV, 100, 130 & 140 - 1
- 210
-
by indy61
Tue Apr 19, 2022 12:16 pm
-
-
-
which voltage regulator?
by cabinetman » Fri Apr 15, 2022 1:48 pm » in Farmall A, Super A, AV, 100, 130 & 140 - 8
- 369
-
by Eugene
Wed Apr 20, 2022 6:31 pm
-
-
-
International 140 Voltage Regulator
by fitzchavis » Tue Jul 06, 2021 12:00 pm » in Farmall A, Super A, AV, 100, 130 & 140 - 2
- 344
-
by Gary Dotson
Wed Jul 07, 2021 7:01 am
-
-
-
3 coil voltage regulator?
by patricktjms » Fri Nov 24, 2023 7:25 pm » in Farmall A, Super A, AV, 100, 130 & 140 - 8
- 947
-
by Jim Becker