Testing an H generator
I have a generator (6volt) off of a 46 H, I would like to test, by belting it to an small electric motor which direction do I need to turn the generator pulley? Clockwise or Counterclockwise . Thanks Dave.
-
- Cub Pro
- Posts: 7760
- Joined: Mon Jun 22, 2009 6:56 am
- Zip Code: 64070
- Tractors Owned: 1942 Farmall AV, serial #87025
1947 Farmall Circle Cub, serial #2116
1948 Farmall Cub, serial #46066 - Circle of Safety: Y
- Location: Lone Jack, MO
Re: Testing an H generator
Engine turns clockwise when viewed from the front. This means that the generator pulley, when viewed from the front, would also spin clockwise (that would be counter-clockwise when viewed from behind the generator).
Cross Ref: http://www.yesterdaystractors.com/cgi-b ... &th=561228
Hope this helps.
Cross Ref: http://www.yesterdaystractors.com/cgi-b ... &th=561228
Hope this helps.
-
- Cub Pro
- Posts: 23701
- Joined: Sun Feb 02, 2003 2:09 pm
- Zip Code: 63664
- Tractors Owned: 47, 48, 49 cub plus Wagner loader & other attachments. 41 Farmall H.
- Location: Mo, Potosi
Re: Testing an H generator
You need to ground the F terminal, and I suggest a battery for a load, without the load, the voltage can go over 35 volts, which is hard on the generator, it is not intended to operate at that kind of voltage.
If you are not part of the solution,
you are part of the problem!!!
you are part of the problem!!!
-
- Team Cub Mentor
- Posts: 20379
- Joined: Fri Jul 02, 2004 9:52 pm
- Zip Code: 65051
- Circle of Safety: Y
- Location: Mo. Linn
Re: Testing an H generator
Easier test. See if the generator will "motorize". If the generator operates as a motor, it will produce electricity.
I have an excuse. CRS.
-
- 10+ Years
- Posts: 518
- Joined: Fri Feb 07, 2003 12:36 pm
- Location: WV, Morgantown
Re: Testing an H generator
I don't know if you can motor a 3 brush generator, being one of the brushes are grounded? If you can, How do you motor test it. Thanks Dave F.
-
- Team Cub Mentor
- Posts: 20379
- Joined: Fri Jul 02, 2004 9:52 pm
- Zip Code: 65051
- Circle of Safety: Y
- Location: Mo. Linn
Re: Testing an H generator
http://www.cleancomputes.com/Cub/Blue%2 ... trical.htm
Page 46. Both the generator case and F terminal is grounded.
Note in the above manual, the internal wiring diagrams for other starters, generators, and starter/generators.
Page 46. Both the generator case and F terminal is grounded.
Note in the above manual, the internal wiring diagrams for other starters, generators, and starter/generators.
I have an excuse. CRS.
-
- Similar Topics
- Replies
- Views
- Last post
-
- 2
- 730
-
by Gary Dotson
Wed May 10, 2023 7:31 am
Return to “Farmall H, HV, Super H, 300 & 350”
Who is online
Users browsing this forum: No registered users and 1 guest